Troubleshoot AtlasMX Power Path

Troubleshoot AtlasMX Power Path

Overview of the Power Path

Adam Doyle is providing some photos for this guide. 
12
Battery -> 0.5m Cable -> Midi Twin Fuse Holder (2 x 30AMP fuses) -> 7.25m Cable -> PCM -> Junction BOX -> Tiger
24
Battery -> 0.5m Cable -> Midi Twin Fuse Holder (2 x 30AMP fuses) -> 7.25m Cable -> Junction BOX -> Tiger

Turn System On

Turn the system on and wait until the monitor is turned on and displaying at least the "camera loading' screen or j-Track. 

Disconnect Battery Connector

Locate and disconnect the 'BATT' connector from the TigerMX. This is on the bottom of the right side.
Once disconnected note if the monitor is still on (interact with the screen just to be sure it isn't frozen), it should still be powered on - if not please me know. 
Reconnect the 'BATT' connector. 
This 2nd part requires someone to check the network connectivity of the system - please give me a call when you're at this stage and I can check this. (or anyone that has access to ping the IP address of that truck)

Disconnect Isolator Connector

Locate and disconnect the 'ISO' connector from the TigerMX, this is above the 'BATT' connector. 
The monitor should turn off but there should still be network connectivity. 
Leave this disconnected for about 30 seconds (this will drain the charge in some internal components). 
Reconnect the 'ISO' connector. The monitor should turn back on quickly. 

    • Related Articles

    • Vehicle Service - Disconnecting Power

      To avoid any power spikes interfering with the Black Moth system we recommend removing power from the system during any vehicle servicing.  ie. welding, battery replacement Note: this process requires the disconnection of a power connector. Review ...
    • Troubleshooting Articles

      Tiger Troubleshoot AtlasMX Power Path GPS - Troubleshooting GPS - Slow to Boot GPS - Antenna Diagnostics GSM Modem Device Not Booting No Touchscreen, No GSM, No GPS GSM False Health States Camera SmartMX Camera Troubleshooting - Internal SmartMX ...
    • TigerMX-5 - How to Reboot / Shutdown / Hard Power Cycle

      Disconnecting the power cables from the TigerMX-5 while in operation may cause component damage and unexpected behaviour.  We recommend that this process is performed before disconnecting any cables from the TigerMX-5. The option to manually and ...
    • System Rebooting / Not Enough Power / Flat Battery

      What it looks like The system will appear to be in a boot loop, displaying the Black Moth Logo splash screen before turning off and repeating this process. Troubleshooting Universe Health Page Look for these 2 Health Indicators:  SENS_ADC - (Analog ...
    • PCM Troubleshooting Guide

      Pre-requisite Multimeter/Voltmeter Testing Measure the Output Voltage of the PCM at the OUT Terminals with a Multimeter/Voltmeter. If the Output Voltage is 13.5 (+/- 0.5V), the PCM is functionally operational. However, if the Output Voltage is low ...